SmartWORKS™ DP

DATASHEET
Get the the datasheet for this product
Download PDF


T1/E1 Passive TAP Card
















SmartWORKS™ DP Series

Key Features and Benefits
• Media Control - CODECS
• Tone Detection / Generation
• CallerID/FSK/DTMF/MF Detection
• Activity / Silence Detectors
• Switching (H.100 and MVIP)
• Automatic Gain Control (AGC)
• Automatic Volume Control (AVC)
• Stereo Recording with AGC
• Echo Cancellation
• Call Progress Monitoring (CPM)
• Full-duplex Channels
• Media Streaming
• Start/Stop Call Recording Triggers

 

 
Software Switchable T1/E1 Interface
Supports T1 and E1 using the same board. Automatically configures for all supported ISDN variants.
ISDN Call State Monitoring Interprets the ISDN signaling protocol and reports the call states and call parameters via comprehensible API events.

True Dual Span Capabilities
A single RJ-45 interface is capable of recording both sides of a conversation, which maximizes the usefulness of each individual port.

On-board DSP to Complete Voice Processing
Robust call recording features combined with ISDN call control, eliminates the need for other resources on the system.

CODEC Support
SmartWORKS™ call recording products offer a large selection of voice CODECS.(including G.723.1, G.729A and MS GSM)

 
 
 

Applications
Click to see how the product functions with the SmartWORKS™ API...>

DP boards are connected between the customer premise equipment (CPE) and the PTSN providing passive monitoring of voice conversation and call control information. Click to see an image

 

HARDWARE SYSTEM REQUIREMENTS
Pentium 4 or equivalent · 2 GHz or better
PCI2.2/PCI-X/PCI-E with 3.3V power supply

Telephony Interface
Trunk type: T1/E1
Trunk Interface Digital High Impedance (Z)
AC Impedance 1k Ohms
Input Impedance 1000 Ohm +/- 5%
Maximum Tap Length 30m (100 feed) of CAT 3 cable
Connectors Two RJ-45 connectors
 
OPERATING SYSTEMS
Windows 2000 · Windows XP
Windows 2003 32 bit· Linux (Call for variant details)

Technical Specifications
Max boards per system: Any combination up to 512 ports
Max ports per system: Up to 512
Resource Sharing Bus: MVIP or H.100
Boards Status: On-board LEDs
Clocking: Master/Slave
T1 Interface
Receive Clock Rate 1.544 MHz +/-200ppm
Transmit Clock Recovered RX clock or 50 ppm
Input Level LBO 0dB to -22dB
Framing SF (D4), ESF
Line Coding AMI, B8ZS
Signaling Protocol ISDN, NFAS, CAS
Clock and Data Recovery Complies with AT&T TR62411
and Bellcore TA-TSY-000170
Loss of Signal Detection ANSI T1.231
Alarm Detection and Integration LOS, LOF, Yellow, and AIS per
ANSI T1.231
Binary Sequence Detector Per ITU-T 0.151
Environmental Conditions
Operating Temperature: 0C to +60C
Storage Temperature: -20C to +85C
Humidity: 8% to 80% non-condensing
Storage humidity: 8% to 80% non-condensing

Physical Characteristics
Form Factor: Full-size PCI card

Power Requirements (6409)
+ 3.3 VDC: 2.8 A
+5 VDC: 5 mA
-12 VDC: n/a
+12 VDC: 20 mA
E1 Interface
Receive Clock Rate 2.048 +/- 175ppm
Transmit Clock Recovered RX clock or 50 ppm
Input Level 3.2V down to 0.45 V
Framing Basic G.704, CRC-4
Line Coding AMI, HDB3
Signaling Protocol ISDN, DASS2, CAS
Loss of Signal Detection per ITU-T G.775
Alarm Detection and Integration LOS, LOSMF, TS16, CRC
Binary Sequence Detector Per ITU-T 0.151
SDK
Ai-Logix Native SmartWORKS™ API
SmartControl (Control Panel)
SmartVIEW (Card functionality test application)

Host Interface
Bus Compatibility: Complies with PCISIG Bus Specifications, Rev. 2.2
Bus Speed: 33 MHz
Bus Mode: 32 bit bus master/target
Audio Signal
Receive range: -68 dBm to + 3 dBm
Input gain control: +24 to -50 dB
Silence Detection: Programmable from API
Transmit volume control: +24 to -50 dB to MVIP/H.100
Automatic Gain Control (AGC): Programmable from API
Automatic Volume Control (AVC): Programmable from API
Activity Detection: Programmable from API
Frequency Response: 300 - 3400 Hz (+/- 3dB)
DTMF Tone Detection
DTMF digits: 0 - 9, *, #, A, B, C, D
Dynamic range: -38 dBm to 0 dBm
Minimum tone detection: 40 ms / programmable
Interdigit timing: 40 ms min.
Acceptable twist: Per LSSGR sec. 6, 8 dB forward,
4 dB reverse
Frequency variation: Accept all +/- 1.5%,
reject all +/-2.5%
Noise tolerance: Per LSSGR sec. 6
Talk off: Bellcore TR-TSY-000762

Safety and Certifications
Telecom: DOC
Emissions: FCC Part 15 class A · EN 55022
Immunity: EN 55024
Safety: EN 60950
Estimated MTBF: 250,000 hours per Bellcore Method I
Audio Digitizing (Encoding & Decoding)
5.3 Kb/s G.723.1
6.3 Kb/s G.723.1
8 Kb/s: G.729A
13 Kb/s: GSM 6.10, Microsoft GSM
16 Kb/s: G.726
24 Kb/s: G.726, OKI
32 Kb/s: G.726, OKI
40 Kb/s: G.726
64 Kb/s: µ-law or A-law per G.711,
8 bit linear PCM (signed & unsigned)
96 Kb/s 6 Khz 16 bit linear PCM(signed)
128 Kb/s: 16 bit linear PCM (signed & unsigned)
Wave file formats: Microsoft GSM, Linear signed
8 & 16-bit PCM
Digitization selection: Programmable per channel, independent
for encode and decode
Models Available
P3209/DP3209-eh: Single E1/T1
DP6409/DP6409-eh: Dual E1/T1  
* -eh denotes PCI-E slot card
 
Part number  
910-0308-002 DP3209
910-0324-001 DP6409
910-0703-001 DP3209-eh
910-0703-002 DP6409-eh
 

PRODUCTS IPX SOFT RECORDER TRB260 NGX DP DT LD TX100 TX1000 RTS BOX
 